The TRITECTOR™ is the practical 3-in-1 solution for the professional refrigeration engineer – with easily replaceable sensors, all common refrigerants, combustible gases and tracer gases can be detected with only one device. The adjustable sensitivity levels find even the smallest leaks, and the ambient concentration is continuously compensated automatically or can also be compensated manually. As soon as a leak is detected, the color LCD display gives a visual signal and an optional sound is emitted. As with other REFCO products, either AA batteries or Micro-USB supplies power - making annoying delays caused by dead batteries a thing of the past.
- Intuitive handling
- Intelligent electronics that automatically detect the connected sensor
- Exchangeable sensors for refrigerants, combustible gases and tracer gases
- Variable power supply (batteries & USB)
- Automatic and manual reset of the ambient concentration
- High quality LCD display
- Technical Data
- Refrigerant [R]: 0.04 oz/yr R134a | Combustible gas [C]: 0.04 oz/yr R290, < 5 ppm methane | Tracer gas [T]: 0.1 oz/yr
- Metal-oxide-semiconductor
- Refrigerants | CFC | HCFC | HCF | HFO | Combustible gases | Tracer Gas
- 16 ″
- 10 y
- 45 s
- 12 h
- IP41
- 4 x AA | Alternative Power Supply USB Mirco-B
- Sensor exchange
Ambient concentration reset:
- automatic
- manual
Peak = peak function indicates maximum measured value
Auto shut off
Sensitivity Level:
- low
- medium
- high
Mute function - +14 °F to +122 °F
- 0 - 90 % relative humidity (no condensation)
- -4 °F to +140 °F
- Batteries | Case | Instruction manual
- Sturdy plastic case
- ABS | TPE
- yellow | green
- Refrigerants: EN-14624:2012, SAE J1627, SAE J2791, SAE J2913
Combustibles: BS 7348
Hydrogen: SAE J2970, EN 35422 - Yes
- Logistics
- 0.39
- 78
- 48
- 260
- 1.62
- 198
- 97
- 420
- 1.23
- 9027.1000
- Documents and Media
- Accessories
- Spare Parts
Further Products
FAQ
Questions about Product
- Which REFCO product can replace the TRACE-LOCATOR?
The TRACE-LOCATOR (leak detector for tracer gas) can be replaced by the TRITECTOR-T (yellow sensor).